Skip to main content

16 July 2026 - Screening Service Degraded - Issue Resolved

Screening search failing for WCO Customers

Root Cause Analysis

1. Incident Summary

Incident Date

16 July 2026

Type of Event

Unplanned

Severity

Sev2

Service Affected

Platform Integration Services

Impact Start

16 July 2026 — 14:13 (Dublin time)

Service Restored

16 July 2026 — 15:43 (Dublin time)

Duration of Impact

Approximately 1 hour 43 minutes

Status

Resolved

2. Detailed Event Narrative

On 16 July 2026, Fenergo deployed a planned infrastructure configuration update to optimise platform resource management. Following deployment, specific services were disrupted for a subset of clients. Fenergo's engineering team identified the issue and notified customer support at 13:53.

The investigation identified the root cause and the issue was remediated.

3. Event Timeline

Time

Event

16 July 2026 — Morning

Planned infrastructure configuration update deployed to production environments.

16 July 2026 — 13:53 (Dublin time)

Fenergo engineering identified service disruption and notified support. Investigation commenced.

16 July 2026 — 14:13 (Dublin time)

Impact window opened. Root cause identified as a permission change affecting platform integration services.

Permissions restored via deployment pipeline. Recovery of affected client journeys initiated where required.

16 July 2026 — 15:43 (Dublin time)

Service confirmed restored across all affected environments. Clients confirmed. Incident closed.

4. Services Impacted

The following services were impacted during this incident:

Service

Impact Description

Platform Integration Services

Screening, external authentication, and external data integration services were disrupted for a subset of clients, preventing completion of integration-dependent workflows.

There was no impact on the accuracy or integrity of work completed prior to the incident. No data loss occurred.

5. Affected Applications and Systems

The Fenergo application was impacted by this incident. The impact was contained to platform integration services. All other areas of the Fenergo application continued to operate normally throughout the incident.

6. Root Cause Analysis

The root cause of this incident was a planned configuration change where the specific impact on platform permissions was not detected by automated testing prior to deployment.

7. Corrective Actions and Corrective Actions Timeline

Fenergo has identified the following corrective action to prevent recurrence:

#

Corrective Action

Target Timeline

1

Enhance automated checks with additional logic to validate infrastructural permission changes prior to production deployment.

Completedd

8. Closing Statement

Fenergo takes the reliability of its platform and the continuity of our clients' operations seriously. We are committed to delivering the corrective action outlined above and to embedding the lessons learned from this incident into our engineering and deployment practices.

We apologise for the disruption caused and thank our clients for their patience and continued partnership with our support teams throughout the recovery process.

Preliminary RCA

On 16th July, a system configuration change temporarily affected access to a required resource on a subset of tenants. Access has been restored and service is operating normally.

13:55 BST

Fenergo alerting picked up issues with WCO/Lexis Nexis screening searches

14:15 BST

Root cause has been identified. Fenergo working on resolution.

14:39 BST

Resolutions are under way with confirmed reports that service has been restored.

15:10 BST

Resolution has been deployed to all tenants. Service has been restored.

15:11 BST

Preliminary RCA will be shared within 24 hours

Did this answer your question?